| Rinnai Infinity 32 - External |
|
 |
 |
| Heavy Duty Available |
= Yes, to order |
| Suitable for |
= 2 Bath & Homes |
| Hot Water Capacity |
= 2.7-26 lt/min, 1560 L/hour |
| W x H x D |
= 350 x 600 x 224 |
| Input (max) |
= 55kW |
| Water Pressure (min) |
= 150kPa |
| Gas Type |
= LPG/NG |
|
| Heavy Duty Available |
= Yes, to order |
| Suitable for |
= 2 Bath & Homes |
| Hot Water Capacity |
= 2.7-32 lt/min, 1920 L/hour |
| W x H x D |
= 470 x 600 x 220 |
| Input (max) |
= 70kW |
| Water Pressure (min) |
= 180kPa |
| Gas Type |
= LPG |
|
|
FAGOR ELECTRONIC GEYSERS
ELECTRONIC IGNITION - Automatic ignition
Electronic Battery-powered Ignition
More convenient to install.
As they are battery-operated, these models do not need to be connected to the mains power supply.
Common Features:
- Brass water valve
- Stainless steel universal burner
- Electrolytic copper heat exchanger coated with aluminium paint
- Battery powered
- On/off switch
- Temperature selector
- Automatic water flow adjuster
- Water inlet filter
- Water inlet stopcock
- Water-shortage safety mechanism
- Vertical outlet non-return draught diverter
- Operation at very low pressures
Since their minimum operating pressure is only 0.12 bar, these heaters can be installed in areas with very low water pressures. In addition, they can operate perfectly at a minimum flow of just 2.3 lt per minute.
Enquire about Fagor Electronic Geysers
|
FEP-15D Plus B LPG / Plus
N Natural Gas |
|
FEP-11D Plus B LPG / Plus N
Natural Gas |
|
 |
 |
W x H x D: 350mm x 648mm x 244mm
Dual Pressure
- Maximum flow: 15 lt per minute
- Ionisation safety
- Electronic battery-powered ignition
- Large LCD display
- Water temperature sensor
- No pilot light
- Temperature selector
- Gas flow control
- Flue sensor
- Interior installation
- Gas consumption: LPG 2,2 kg/h
- Gas consumption: Natural Gas 3,08 m3/h
- Flue connection: 130mm diameter
|
W x H x D: 310mm x 567mm x 230mm
Dual Pressure
- Maximum flow: 11 lt per minute
- Ionisation safety
- Electronic battery-powered ignition
- Large LCD display
- Water temperature sensor
- No pilot light
- Temperature selector
- Gas flow control
- Flue sensor
- Interior installation
- Gas consumption: LPG 1,74 kg/h
- Gas consumption: Natural Gas 2,34 m3/h
- Flue connection: 110mm diameter
|
|
| FEP-6 B LPG / N Natural Gas |

|
W x H x D: 312mm x 566mm x 230mm
Dual Pressure
- Maximum flow: 5,41 lt per minute
- Ionisation safety
- Electronic battery-powered ignition
- No pilot light
- Temperature selector
- Gas flow control
- Flue sensor
- Interior installation
- Gas consumption: LPG 0,8 kg/h
- Gas consumption: Natural Gas 1,4 m3/h
- Flue connection: 90mm diameter
|
|
FAGOR SPARK IGNITION GEYSERS
SPARK IGNITION
Maximum convenience and reliability.
Silent and effortless pilot flame ignition.
Simply press the ignition button and a series of sparks will light the pilot light.
Spark ignition uses a 1,5 V easy-to-install battery that lasts for about two years under normal usage.
Control Unit
- Spark ignition
- Ignition and power selector handle
- Temperature selector
Brass Water Valve
- Made with top-quality materials for excellent performance.
- Stamped and machined brass provides greater reliability and strength in high water pressure areas (up to 13 bar).
- Anti-scaling mechanism for optimum functioning in hard-water areas.
- Lower noise levels thanks to special design.
Enquire about Fagor Spark Ignition Geysers |
| FTC-11 B LPG / N Natural Gas |
|
| FTC-6 B LPG / N Natural Gas |
|
 |
 |
W x H x D: 312mm x 566mm x 230mm
Dual Pressure
- Maximum flow: 11 lt per minute
- Chispamatic spark ignition
- Battery powered
- Temperature selector
- Gas flow control
- Brass water section
- Flue sensor
- Water overheat sensor
- Interior installation
- Gas consumption: LPG 1,74 kg/h
- Gas consumption: Natural Gas 2,3 m3/h
- Flue connection: 110mm diameter
|
W x H x D: 312mm x 566mm x 230mm
Dual Pressure
- Maximum flow: 5,4 lt per minute
- Chispamatic spark ignition
- Battery powered
- Temperature selector
- Gas flow control
- Brass water section
- Flue sensor
- Water overheat sensor
- Interior installation
- Gas consumption: LPG 0,8 kg/h
- Gas consumption: Natural Gas 1,4 m3/h
- Flue connection: 90mm diameter
|
|
UNFLUED GAS HEATERS
Enquire about Unflued Gas Heaters |
|
|
 |
 |
W x H x D: 610mm x 482mm x 239mm
LPG Gas Consumption:
Low: 0,13kg/hr, High: 0,54kg/hr
Colours: White or Platinum Silver
- Large heating capacity - up to 85m2 or a volume of 204m3
- Rinnai peace of mind safety system: oxygen depletion, flame failure and tilt switch shut down systems.
- Electronic ignition controls with a thermostat for accurate temperature control and a programmable clock timer set and
forget heating.
- Quiet, high performance filtered multi-speed fan, with air outlet at floor level, provides rapid spread of warmth.
- Convenient remote control operation.
|
W x H x D: 487mm x 492mm x 243mm
LPG Gas Consumption:
Low: 0,09kg/hr, High: 0,28kg/hr
Colours: White or Platinum Silver
- Medium heating capacity - up to 44m2 or a volume of 106m3
- Rinnai peace of mind safety system: oxygen depletion, flame failure and tilt switch shut down systems.
- Electronic ignition controls with a thermostat for accurate temperature control and 24 hour delay timer.
- Quiet, high performance filtered multi-speed fan, with air outlet at floor level, provides rapid spread of warmth.
|
|